Carbon and Sulfur Analyzers

High-frequency induction furnace and resistance furnace analyzers delivering precise carbon and sulfur determination in metals, ores, coal, and cement per ASTM E1019, ASTM D4239, and ISO 15350 standards.

Available Instruments (8)

Parr · Orlab · Sylab · Elite
CSBox DCS Analyzer BKP
NCS Testing Technology

CSBox DCS Analyzer BKP

CSBox DCS Analyzer Overview CSBox DCS analyzer enumerates the way to determine carbon and sulphur in inorganic samples like steel, ores, finished metals and other inorganic samples.

View details
CSBox HFA C Analyzer
NCS Testing Technology

CSBox HFA C Analyzer

CSBox HF Analyzer is used to determine Carbon in Inorganic samples like steel, Iron, ores, finished metals and other inorganic samples.

View details
CSBox HFA CS Analyzer BKP
NCS Testing Technology

CSBox HFA CS Analyzer BKP

CSBox HFA CS Analyzer Overview CSBox HF Analyzer is used to determine Carbon and Sulfur in Inorganic samples like steel, Iron, ores, finished metals and other inorganic samples.

View details
CSBox HFA S Analyzer
NCS Testing Technology

CSBox HFA S Analyzer

Home Analytical Instruments Elemental Analyzers Carbon and Sulfur Analyzers CSBox HFA S Analyzer CSBox HFA S Analyzer Overview CSBox HF Analyzer is used to determine Sulfur in Inorganic samples like…

View details
CSBox Tube C Analyzer
NCS Testing Technology

CSBox Tube C Analyzer

CSBox Tube C Analyzer The CSBox Tube C Analyzer is used to determine carbon in variety of organic and inorganic materials such as coal, coke, oils, animal feed and biomass, cement , floors, etc.

View details
CSBox Tube CS Analyzer
NCS Testing Technology

CSBox Tube CS Analyzer

CSBox Tube CS Analyzer is used to determine Carbon and Sulfur in Organic samples like coal, coke, fuel oils, soil, biomass and other organic samples.

View details
CSBox Tube S Analyzer
NCS Testing Technology

CSBox Tube S Analyzer

CSBox Tube S Analyzer The CSBox Tube S Analyzer is used to determine sulfur in variety of organic and inorganic materials such as coal, coke, oils, animal feed and biomass, cement , floors, etc.

View details
Carbon & Sulfur Analyzers
NCS Testing Technology

Carbon & Sulfur Analyzers

High-frequency infrared carbon & sulfur determination

View details

Technical Overview & Analytical Methods for Elemental Analysis

Elemental analysis quantifies the fundamental chemical building blocks—carbon, hydrogen, nitrogen, sulfur, and oxygen—across inorganic and organic matrices. For inorganic materials such as steel, cast iron, cement, and ores, samples undergo high-frequency induction furnace combustion in pure oxygen, transforming carbon to CO2 and sulfur to SO2 for detection by solid-state non-dispersive infrared (NDIR) sensors. For organic samples, flash dynamic combustion coupled with thermal conductivity detection (TCD) provides simultaneous CHNS separation.

Measurement Principles & Technology

  • High-Frequency Induction Combustion: Delivers rapid, clean heating exceeding 2200°C in an oxygen stream to ensure total release of bound carbon and sulfur.
  • Non-Dispersive Infrared (NDIR) Detection: Solid-state infrared cells equipped with optical filters measure specific absorption bands for low-ppm and high-percentage concentrations.
  • Inert Gas Fusion (IGF): Refractory metals in graphite crucibles are melted in helium or argon carrier gas to extract oxygen as CO/CO2, nitrogen as N2, and hydrogen as H2.
  • Flash Dynamic Combustion: Organic CHNS matrices are combusted at 1050°C with an oxygen pulse, chromatographically separated, and quantified via high-sensitivity TCD.

International Standards & Regulatory Compliance

ASTM E1019Compliance

Standard Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys

Industry benchmark for metallurgical quality control and foundry testing.

ASTM D4239Compliance

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Essential for environmental emissions compliance and fuel grading.

ISO 15350Compliance

Steel and Iron — Determination of Total Carbon and Sulfur Content

International standard for infrared absorption after combustion in an induction furnace.

ASTM D5373Compliance

Standard Test Methods for Determination of Carbon, Hydrogen and Nitrogen in Analysis Samples of Coal and Carbon in Coke

Organic elemental characterization of solid fossil fuels.

Core Industrial Applications

Steel Mills & Foundries

Fast melt chemistry verification, verifying ultra-low carbon in automotive steels, and sulfur inclusion monitoring.

Mining & Ore Beneficiation

Quantifying total sulfur in iron ore, bauxite, limestone, and base metal concentrates.

Chemical & Polymer Research

CHNS empirical formula confirmation, pharmaceutical purity testing, and catalyst characterization.

Environmental Testing

Soil carbon sequestration studies, total organic carbon (TOC), and organic pollutant monitoring.

Laboratory Selection Checklist

Combustion Method: Induction furnace for conductive inorganic metals and ores; resistance furnace for coal, biomass, and petroleum.
Detection Range: Dual-range infrared detectors allow measuring trace ppm levels up to 100% concentrations without hardware recalibration.
Autosampler Capacity: Automated pneumatic carousels enable unattended multi-sample analysis for high-throughput commercial labs.

Why Laboratories Across India Partner with Orbit Technologies

Established in Hyderabad in 1995, Orbit Technologies manufactures and represents world-class scientific instruments. As Parr Instrument Company's exclusive partner and #1 Global Dealer for new orders, we provide full end-to-end support: from testing application guidance and custom engineering to factory-certified installation, NABL-traceable calibration, and lifetime spares.

Pan-India Support Network

14 Dedicated Sales & Service Branch Locations:

Hyderabad · Delhi · Mumbai · Kolkata · Chennai · Bangalore · Pune · Nagpur · Lucknow · Baroda · Bhubaneswar · Bilaspur · Raipur · Ranchi

Direct Sales Desk:+91 - 81438 85547

Common Technical Questions: Carbon and Sulfur Analyzers

Key questions on testing standards, operating methods, maintenance, and calibration.

Induction furnaces couple directly with conductive metallic accelerators (tungsten and iron chip) to reach temperatures exceeding 2200°C within seconds. This ensures complete liberation of entrapped carbon and sulfur even from refractory carbides and nitrides, with typical cycle times under 45 seconds.

Need Expert Selection Assistance for Your Laboratory?

Orbit Technologies supports laboratories across India from instrument selection and purchase through installation, commissioning, operator training, and preventative maintenance.